balboa spa troubleshooting

Balboa Spa Controllers. Balboa Spa Wiring Diagram - This balboa spa control wiring diagram graphic have been authored. Balboa GL and GS Spa Control Troubleshooting & Service Manual 230V Part 1.pdf. • A short in the heating element. A few of the possible causes of this can be easy to identify and fix, such as: • Debris in the pump system. Balboa's BP Troubleshooting & Service Manual SPA CONTROL SYSTEMS PANELS60 Hz BP500 BP2000G1 TP900, TP800, TP600, TP400 THIS MANUAL COVERS THE FOLLOWING: 2Manufactured under one or more of these patents. If the sensor reads a temperature above 118° F, the high-limit relays will open and the spa will shut down. BALBOA Control Panels User Guide TP500 and TP500S Control Panels. Test A Heater For Resistance2. Troubleshooting & Servicing Spa and Electrical Equipment.. Volt / 50 Hz Residential Wiring Schematic with 2 Pole RCD Breaker Box. Filter cycles are f2 through f8, and fc which is continuous. Each function will echo from the circuit board to the LCD in a corresponding manner. SL: Indicates spa is in Sleep mode: SF: Safety Suction . SpaGuts specializes in replacement components for your spa's mechanical and electrical systems. Troubleshooting & Service for EL/VS Systems 60 Hz 1. Balboa Hot Tub Not Heating - Troubleshooting Steps. Spa Behavior Pumps. With no sensors plugged in, the hot tub will show warning signs, by flashing the LED lights, and displaying a number of errors on the screen. If in sleep mode the heater is disabled, but pump can still run for heat call. Inspect the pipes and the impeller surfaces for any deposits. (Displays on the 5th occurrence of "HFL" message with 24 hours). . How M7 electronics and systems work is that the spa first starts up in priming mode and the pumps are manually checked during startup (4 minutes) to be sure they are all full of water and operational. At that point the pumps are all primed and the heater is full of water too. Best rated above-ground hot tub spa repair and service provider in Los Angeles, CA. Pr: When spa is first actuated, it will go into Priming Mode. The display will flash . Part #54357-03 is the most recent version, and . Set the jets on high for 10 to 15 seconds to force the air out of the pumps. Cut off your power, close valves on each side of the pump, and remove the wet end cover plate to inspect the impeller. It could also be the spa cover allowing heat to escape. These application notes have been created by individuals with a great deal of experience and expertise in the hot tub industry. Repair Chemicals Spa Frog Cartridges Water Purification & Generators Air Systems 110v, 60hz Blowers 220v, 60hz Blowers Blowers Export 50hz Replacement Blower Motors does not authorize attempts by the spa owner/user to repair or service any Balboa products. SnS or Sn is Alternating with Temp: Possibly the "Sensors are out of Sync" (SnS or Sn) with Each Other. The idea is that the rice will soak the moisture out of the control panel and with a little bit of luck it might start working properly again. A spa's GFCI (or Ground-Fault Circuit Interrupter) breaker tripping is a common problem and most of the time an easy fix. You may obtain your copy of the video by contacting Balboa Direct at our toll free number, 1-800-645-3201. The major components are the SPA CONTROLLER, SPA BLOWER , SPA PUMP, and SPA HEATER. Buy Now . Reduced Heat . If your spa's jets can be manually adjusted, open them up all the way and ensure that all diverter valves are in the open position. Additionally, it should draw at least 15-25 amps at 240v, and have 9-12 ohms of resistance. Your spa heater assembly is a metal tube that contains a heating coil. One of the most likely offending hot tub components is the heating element. The Sensors are Possibly Out of Sync with Each Other, or Not Indicating Close to the Same . Test A Heate. (---) Unknown water temperature. LF = Persistent low flow problems. Step 6: Restore the power to the spa. You are able to get . In this case, you may need to replace the sensor. Test A Heater For Voltage3. . User Guide for Standard Menu System Model: All BP series systems Panel Model: TP500 and TP500S Series . The cost to bench test is 125.00, if the circuit board is cost effective to repair that Price will be applied towards. To download, select text in blue TP400 & TP600 You Tube Quick Set Up Guide for TP400 . 2. Balboa VS501z Ciruit Board Balboa P/N 54357-03 Replacement Circuit Board for VS501Z spa Pack PN 54357-03 is the current version of the circuit board used in VS501Z spa packs. ADD TO CART CHECKOUT NOW. Ecn: Spa operating in Economy Mode. Common causes are loose wire connections, loose heater connections especially, insect or rodent damage, water damage, or relay or transformer . (Priming Mode). Algae growth can quickly get out of control if left untreated, so if you notice algae beginning to grow it is important to treat your Balboa spa with a quality . If the problem is solved, replace the sensor set. Control System, Balboa, VS520SZ, (NO Topside or Cords), 5.5KW, 56007, G5157 . Balboa VS, BP and GS spa packs and replacement parts including Balboa heaters, heater elements and circuit boards for many hot tub models in Canada. Balboa VS501z Hot Tub Heater . Spa Behavior Pumps. The service video and technical service manual are designed to aid you in all your spa repair needs. It is pretty easy to tell if there is a problem with the temperature because your hot tub will be cold or warm. Balboa Instruments does not authorize attempts by the spa owner/user to repair or service any Balboa products. Spa System Box VAC Service Bottom view of G.F.C.I Volt Residential Wiring Schematic with G.F.C.I. This Balboa® printed circuit board (PCB) is for SUV M7 hot tub control systems. This code is an abbreviation for sensor, and the letter (or sometimes a number) indicates which sensor is malfunctioning or out of balance. Compatible with Lite Duplex or Mini Oval Digital topside control keypads. Each function will echo from the circuit board to the LCD in a corresponding manner. It can also appear when the connection between the sensor and circuit board is wonky, or when your circuit board is fried. 30 year's experience specializing in spa circuit board repair and spa control repair, we repair all spa brands. Replaces control systems in many spas. You could have scale deposits: Calcium or lime deposits can build up and create noise. This video describes the show you how to troubleshoot the BP2000 spa system heater:1. View as Grid List. . Check for condensation under display glass. First, check and test your heating element. Hottubsuppliers & The Balboa Water Group Quick Set Up Guide To The GS100 System.Hot Tub Suppliers are proud to be recognized as official Balboa suppliers of . • Dirty filter. Clean plug-in cable connections on both ends. You are able to get . Software version is 43. Works with Balboa BP501 spa pack #56713. Some smaller Balboa spas have had problems with water quality. Updated. Test A Heater For Resistance2. Heater modes are standard, economy, and sleep. TeeBone. ADD TO CART CHECKOUT NOW. Don't worry, you will not get shocked as the pins are low voltage. Poor water circulation can be caused by not running the pumps long enough. Spa frames are normally just wood. This board is compatible with the following Balboa parts: 52144 Topside Panel, 52487 Topside Panel, 51676 Topside Panel, 30382 or 32016 M7 . Press the "Jets" button once to turn pump 1 on or off, and to shift between low and high speeds if equipped. Test A Heate. Troubleshooting & Servicing Spa and Electrical Equipment.. Volt / 50 Hz Residential Wiring Schematic with 2 Pole RCD Breaker Box. In this video The Spa Guy tells you the basics about Relays for repairing Balboa Boards. This is a Balboa vs series spa pack installed on an in ground spa. My spa is running a Balboa PVS500Z control pak/heater and a few weeks ago the spa was going way beyond the heater set point. Posted June 18, 2021. (Displays when first powered up after refill). • Defective parts like: pressure switch, cable, or the circuit board itself. All material copyright of Balboa Water Group. The Spa Care Center specializes in carrying a variety of spa parts to ensure spa owners can make their own repairs. For detailed component settings and wiring configurations, service technicians should obtain the latest technical manuals (Tech Sheets) available. Go to our eBay Store American Spa parts or www.spaguypa. Balboa VS501 & VS501z Replacement Board-PN 54357-03. Though it can be caused by a host of possible parts, determining the problem part will take some troubleshooting and repairs will require working with electricity. Balboa (used by LifeCast Spas and many other hot tubs) pd = Power supply, unit running on battery backup OH = Sensors reading 112-118° F. OHH = Overheat. M7 58083 Spa Replacement Heater C2550-0807-TPS The 58083 spa replacement heater is specially designed by Balboa Water Group and is one of the most popular models of replacement heaters. attempts by the spa owner/user to repair . This Balboa® printed circuit board (PCB) is for VS500 & VS501Z hot tub control systems. Unplug the pressure switch cable from the circuit board, thus revealing two pins. While in the tub the other night, the tub shut-down. TeeBone. Fast Free shipping!, Shop for Balboa VS Spa Control Kit - 2 Pump + Circ Pump, Upgradable to 3 Pumps at SpaDepot.com, Digital Control Packs, , EP6551 Balboa spa packs are available at very reasonable prices below $800 with discounts ranging from 20 to 37% off. Std: Spa operating in Standard Mode. Water chemistry problems (PH imbalance) causes corrosion on the pump seals and negatively affects circulation. If you click this link and make a purchase, we earn a commission at no additional cost to you. As soon as the low/filter pump turns on, jump the two pressure switch pins on the board with alligator clips. This video describes the show you how to troubleshoot the BP2000 spa system heater:1. For optimum flow, you should run your pumps for one hour for every 10 degrees of temperature. With the the Pump ON, prior to Heater ON, the Sensors differ by more than 2°F (1.0°C), indicating one or both Sensors are several degrees off. Details. Page. Follow. Topside - Balboa TP600CE 6-button Digital (#50015) $199.84. Algae can be a big problem with any spa, and it is important to deal with an algae problem at the first sign of trouble. Replacement Balboa Circuit Board, Value Board, Chip ValueR1. This is a 5.5 kW heater that is compatible with the Balboa systems listed in our product listing. Portable Hot Tubs & Spas ; Balboa Circuit Board Problems Balboa Circuit Board Problems. 54604-01 Balboa | Circuit Board, Balboa, VS300FLX, Duplex, 8 Pin Phone Cable $234.44 Plug Connection - Phone Style Cable Chip Number - VKV300F41RA, VS300FLXR1B, NORVS300R1A, FREE300(x) The plugs must be clean. Find a rectangular container and fill it with ordinary cooking rice. Share ALSO SEE LINK TO THE 10-175-6775 SPAGUTS VS300 CIRCUIT BOARD AS AN ALTERNATIVE REPLACEMENT OPTION. M7 Control System Functions. OEM part number 54604-02. 2 MB Download. With flat rate pricing, this gives you the assurance that repairs will get done with no hidden, run away charges. They offer same-day service as well as 24/7 emergency coverage for all of our loyal customers throughout. The most popular spa controllers are Gecko IN.XE and Balboa brands. Balboa's Patented M7 Technology TOPSIDE CONTROL PANEL The control panel activates functions at the touch of a button. Reply to this topic; Start new topic; Recommended Posts. Bad Heating Element. IT WORKS THE SAME, IS ALSO MADE BY BALBOA, AND AT A DISCOUNTED PRICE. Put the control panel inside the container and bury it in the rice. . The control panel became inoperative and the LED display went blank. All material copyright of Balboa Water Group. • Blown fuse. Ahmed. Non-qualified users should never open or remove covers, as this will expose dangerous voltage . Balboa VS Series hot tub control pack w/ keypad. The reason that the heating would fail is because the heating coil has failed. Gecko spa controls are also available at the same reasonable prices from a little above $500 to less than $900, also at discounted prices with 20 to 25% off. 120V/240V Factory preconfigured for your spa. aid qualified spa service technicians in troubleshooting and repairing spas with control systems manufactured by Balboa Instruments, Inc. Balboa controls have absolutely no end user serviceable parts. Step 8: Re-connect the sensor connections to the circuit board. In this video The Hot Tub Professor tells you about M7 Sensors on Balboa Spa Hot Tub Control Systems. It uses Balboa's revolutionary M7 technology to deliver consistent results. . Check cable for crimps or any visible damage. Balboa's BP Troubleshooting & Service Manual Balboa User Manuals BALBOA USER GUIDES. Important Note: To troubleshoot your spa, you will not only need basic tools, but will also need a multi-meter that can check for Voltage and Resistance (Ohms). day priority for small packages and UPS Ground for large shipments, unless customer . By TeeBone, June 18, 2021 in Portable Hot Tubs & Spas. M7 TECHNOLOGY With many years of experience we want to bring our services to anyone with a hot tub circuit board problem. I have a 6-month old tub with a Balboa SUV spa pack. Then press Temp once to exit Priming Mode. One frequently asked question is about the "FLO" displaying constantly or intermittently. Spa is shut down. 1 year ago. Temperature Sensor (in the spa) High-limit Sensor (at the heater) www.balboa-instruments.com 5 6 800.645.3201 Balboa's Patented M7 Technology TOPSIDE CONTROL PANEL The control panel activates functions at the touch of a button. Balboa Spa Packs VS500S, VS501S and VS510S are available with the M7 features. This board can also replace earlier versions of the board such as 54357-01. Power up the system. Circuit Board Troubleshooting Tip #4 - Replacing a Spa Circuit Board. The pump is cycling on and off and the indicator light is blinking. Check power at Transformer on control circuit board. Balboa Spa Wiring Diagram - This balboa spa control wiring diagram graphic have been authored. Balboa BP2000 Spa Heater. Check us out at. SpaGuts P/N: 10-175-4161. If the spa heater is not giving enough heat, it means a water flow problem from dirty filters or partially closed valves or clogged pumps. This is my second spa and the first time I've even encountered this situation. There are 2 kinds of spa heater problems - not enough heat or totally no heat. You're currently reading page 1; Page 2; Page Next; Sort By: Set Descending Direction. Nothing I tried would cool it down so eventually I cut the GFCI to let it cool. If your Balboa system is still not working properly, feel free to contact our office at (858) 292-5625, and they will send a tech over immediately for fast and affordable repair services. Heater is shut down, but other spa functions run normally. This circuit board operates Pump 1 dual speed, ozone, and a 12V light. How to Repair and Replace a Spa Blower. Add to Cart. F2 is two 2 hour cycles each day, for a total of 4 hours per day, and f8 is 16 hours per day. Replacement Balboa circuit board for the VS300FLX spa controller model. This sensor must cool down to 110° F before the spa can be manually reset by touching a panel button. Check that topside control number works with spa control chip . You can test your heater with any multi-meter and amp meter, or with an Ohm meter. We offer hot tub parts, Balboa hot tub parts, Gecko spa parts and more to ensure spa owners have any part they need. Balboa GL & GS Spa Control Troubleshooting & Service Manual Part 1. Spa System Box VAC Service Bottom view of G.F.C.I Volt Residential Wiring Schematic with G.F.C.I. Leave it overnight. Check power at fuse on spa control circuit board. Press the "Jets" button once to turn pump 1 on or off, and to shift between low and high speeds if equipped. Poor Water Circulation. Balboa Video Service Guide The Balboa Video Service Guide is the perfect companion to the Balboa Technical Service Manual. Lighting: This circuit board will only run one light, either a 12V light or Fiber Optics light. Spa has shut down. They can be removed easily with a stiff brush. The panel will also display diag-nostic messages that enable the service technician to easily troubleshoot the system. Be sure to first take your heating elements out . Balboa GL and GS Spa Control Troubleshooting & Service Manual Part 2 - Spa Store Help Centre Spa Store Help Centre Manuals Balboa® Balboa GL and GS Spa Control Troubleshooting & Service Manual Part 2 Ahmed December 26, 2021 20:04 Updated Follow Balboa GL and GS Spa Control Troubleshooting & Service Manual 230V Part 2.pdf 1 MB Download There are, however, some tips that require nothing but simple observation. Share More sharing options. Members; 6 Report . If after two minutes you cannot verify that water from the circ pump is flowing because the water motion from pump 1 obscures it, press the Jets 1 button again until all pumps turn off. Genuine OEM Board. Portable Hot Tubs & Spas ; Troubleshooting Dead Balboa VS510SZ Troubleshooting Dead Balboa VS510SZ. Product Notes: Part #52532-02 is the most recent version, and replaces older . This is a Balboa vs series spa pack installed on an in ground spa. Turn the spa on and set the heater to below ambient temperature to avoid damaging it. Spa Circuit Board Repair. . It would be impossible to troubleshoot your spa without one. At some point, spa owners will face hot tub or spa heater problems. Hot tub manufacturers that adhere to these recommended industry practices will ultimately improve the quality and reliability of the control system and will experience greater performance and longevity throughout their entire product line. Non-qualified users should Related to Sure Spa After April 2017, Milano Deluxe, Vancouver - After November 2017 If you aren't sure how to complete the repair, our experts will ensure you purchase the right parts and will . Product Notes: Ozone and circ pump must be the same voltage. ILOC: Interlock failure - possible pump or ozone spike. We also offer in-house board repair as well as Videos of how to repair the board. • Jets either not installed correctly or too many turned off at once. Unplug the sensor set (at the temp/high-limit jumper) and plug in the test sensor set. .. . Step 7: Power off the spa. The panel will also display diag- nostic messages that enable the service technician . 6. Keep in mind there is no high-limit sensor protecting the heater during this test. Unless the water is very cold, only the circ pump will start for one minute. Supports a 2-speed primary pump, 1 or 2-speed secondary pump or a blower, ozonator/UVC, light. The heating coil controls the heat that the water is, and is better off just to replace it than to fix it. Test A Heater For Voltage3. The pump is cycling on and off and the indicator light is blinking. BALBOA Control Panels User Guide TP500 and TP500S Control Panels. OEM part number 54161. Balboa's BP Troubleshooting & Service Manual SPA CONTROL SYSTEMS PANELS 50 Hz BP600 BP2100G1 TP900, TP800, TP600, TP400 . Together these comprise the SPA PACK, The secondary components are the SPA OZONATOR , SPA FILTER SYSTEM, and the SPA GFCI. Reset Spa Controller, power down and restart. Balboa BP2000 - G1 5.5Kw Digital Spa Controller - Wireless Smart Phone Integration &. If you find that your circuit board is damaged, pay close attention to where it was damaged, and think hard about why it was damaged. Balboa General Troubleshooting FAQ Balboa prides itself on producing a professional product and recommends that you seek professional assistance instead of attempting repairs yourself. Make sure the batteries are fresh in the meter to insure you get accurate readings. Power down the circuit board. spa side and into the water. If your heating element is in good shape, it should be between 4.0 and 5.5kw. Followers 1. Step 9: Replace the covering on the spa control system, and power up the . By kengorman, January 16, 2008 in Portable Hot Tubs & Spas. Hang the test sensors over the. This manual is for general servicing of BP Control systems, and troubleshooting typical spa control system problems. User Guide for Standard Menu System Model: All BP series systems Panel Model: TP500 and TP500S Series . As in the spa was hitting 108 degrees plus. Supports a 2-speed primary pump, 1-speed secondary pump or a blower, optional circulation (circ) pump, ozonator/UVC, stereo & light/fiber optics. Balboa VS501Z Spa Control System, 4.0KW HTR, (No Topside/Cords), G4152 (SPECIAL ORDER) $499.95.

balboa spa troubleshooting